Piping
Trade lead: Marcus Lee, Ironwood Piping · Everything saved here shows live on the PM and CM screens.
Owner: Piping Lead · Readers: Construction Manager, Project Manager · Trades: PIPE · Foreman view · Enter on this board
Is this page current? All feeds OK
Exceptions requiring attention
Nothing past its needed-by date.
Watch list profile
Delays on this trade
No open delays on this trade.
Changes and back-charges
Budget $1,320,100 · approved changes $232,500 · revised $1,552,600 · pending $0 · back-charges open $0 · value returned $0
No pending change orders or open back-charges.
From front-end loading
No open front-end findings on this trade.
From meetings
ACTION Marcus Lee to confirm the condensate header replacement spool dimensions for SY010 by 2026-08-17. watch item MTG-2-14 · Weekly Outage Coordination, day 11 2026-08-15, line 16
Next shifts
| Activity | Area | Contractor | Planned | % |
|---|
Crane sequence
No lifts in the next 7 days.
Drawings
| Number | Title | Held | Doc control | Status |
|---|---|---|---|---|
P-3300-ISO-01 | Steam joint and syphon isometric, D-01 to D-07 | AB | AB | CURRENT |
P-3300-ISO-02 | Steam joint and syphon isometric, D-08 to D-14 | AB | AB | CURRENT |
P-3300-ISO-05 | Condensate header replacement (CO-001) | AB | AB | CURRENT |
P-PID-330 | Dryer steam and condensate P&ID | AB | AB | CURRENT |
Prints for this trade
Current revisions only, filed by trade as they are received. Older revisions are kept by the PM.
| Number | Title | Rev | Trade | Received | |
|---|---|---|---|---|---|
P-3300-ISO-01 | Steam joint and syphon isometric, D-01 to D-07 | AB | PIPE | 2026-09-23 | Open |
P-3300-ISO-02 | Steam joint and syphon isometric, D-08 to D-14 | AB | PIPE | 2026-09-24 | Open |
P-3300-ISO-05 | Condensate header replacement (CO-001) | AB | PIPE | 2026-09-25 | Open |
P-PID-330 | Dryer steam and condensate P&ID | AB | PIPE | 2026-09-26 | Open |
Photos: progress and evidence
No photos yet. Use Take a photo on a phone or tablet to open the camera.
Milestones
No milestones for this trade.
Budget and earned value calculated
| Account | WBS | Budget | Earned | Actual | Forecast |
|---|---|---|---|---|---|
| PIPE-2.2-A90 | 2.2 · A90 | $404,100 | $404,100 | $412,200 | $412,200 |
| PIPE-4.2-A80 | 4.2 · A80 | $673,500 | $673,500 | $687,000 | $687,000 |
| PIPE-5.1-A30 | 5.1 · A30 | $53,900 | $53,900 | $55,000 | $55,000 |
| PIPE-8.1-A30 | 8.1 · A30 | $421,100 | $421,100 | $429,500 | $429,500 |
Manpower and daily logs
| Date | Contractor | Log | Headcount | Crew hours |
|---|---|---|---|---|
| 2026-10-22 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-21 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-20 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-19 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-18 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-17 | Ironwood Piping | read | 0 | 0.0 |
| 2026-10-16 | Ironwood Piping | read | 0 | 0.0 |
Shift turnover
No turnovers.
Field log
No entries.
Safety observations
2026-09-16 Hydro test boundary barricaded and signed; good. Referred to Site Safety Lead
2026-09-09 Hydro test boundary barricaded and signed; good. Referred to Site Safety Lead
2026-09-04 Hydro test boundary barricaded and signed; good. Referred to Site Safety Lead
2026-08-30 Hydro test boundary barricaded and signed; good. Referred to Site Safety Lead
2026-08-25 Hydro test boundary barricaded and signed; good. Referred to Site Safety Lead
Enter on this board
Each entry records your name. Changes show on this board, the CM roll-up and the master board straight away.
Watch list: add or change an item
Record a decision
Add a shift turnover
Add a field log entry
Record a safety observation
Forms and sign-off cards
- Hydro test package
- Weld map sign-off
- Line walkdown