SAMPLE PROJECT · Completed job · Invented data, read-only · Back to xpcspine.com
XPC Spine PM3-REBUILDPaper Machine 3 Press and Dryer Section Rebuild
Help
OverviewPre-task plansPermitsInspectionsCorrective actionsIncidents and near missesStop workToolbox talksObservationsTraining and cardsLift plans

Safety control center ?

Safety comes first on this project. Every pre-task plan, permit, inspection, corrective action, incident, stop-work and toolbox talk is recorded here with who entered it. Anyone may stop work. Safety reports stay open to every field supervisor at all times.

No names or medical details. Record what happened, where and why. The injured person's name and any medical information stay in the confidential medical and HR records, never here. The PM, construction manager or superintendent confirms the classification against 29 CFR 1904.7.

Incidents and near misses

RefDateKindTradeWhat happenedImmediate actionRoot causeDays away / restrictedActionsConfirmed
INC-0032026-08-18NEAR MISSPIPE
Ironwood Piping
Residual condensate sprayed from a flange when the bolts were cracked. The line was locked out but not fully drained. The fitter's face shield took the spray; no injury.
Basement, drive-side condensate header
reported by Marcus Lee
All drive-side line breaks stopped until drained and verifiedLine break permit did not require a drain-and-verify step at the low point SA-004 Carl Mendez, Superintendent
2026-08-18
Investigate
INC-0022026-08-15FIRST AIDMILL
Northfield Millwright Services
A millwright pinched a finger between the spreader beam and a dryer journal while guiding the landing. First aid at the site station; back to work the same shift.
Dryer section, tending aisle
reported by Dale Whitaker
Landing guided by tag lines onlyHand on the load during landing instead of a tag line SA-003 Elena Varga, CM
2026-08-16
Investigate
INC-0012026-08-10NEAR MISSRIG
Apex Rigging and Crane
A shackle pin dropped from the blow box level into the barricaded tending aisle while a rigger changed the hitch. No one was inside the barricade.
Dryer section, blow box level (128 ft)
reported by R. Okafor
Work paused; pins and small tools tethered at heightLoose shackle pin not tethered while the hitch was changed at height SA-002 Carl Mendez, Superintendent
2026-08-11
Investigate
Source: safety_incident, safety_action